Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113501, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461431

RESUMO

The EAST plasmas heated with deuterium neutral beam injection and ion cyclotron resonance heating (ICRH) have been simulated by the TRANSP code. The analysis has been conducted using the full wave solver TORIC5, the radio frequency (RF)-kick operator, and NUBEAM to model the RF heating effects on fast ion velocity distribution. In this work, we present several simulated results compared with experiments for high power EAST scenarios, indicating that the interactions between ICRH and fast ions can significantly accelerate fast ions, which are confirmed by the increased neutron yield and broadened neutron emission spectrum measurements.

2.
Rev Sci Instrum ; 92(4): 043552, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243473

RESUMO

Neutron emission spectroscopy and neutron yield measurements are important for high neutral beam injection (NBI) power heating at the Experimental Advanced Superconducting Tokamak (EAST). The neutron yields mainly depend on the deposition from NBI to the deuterium plasmas in the EAST. We have recently used TRANSP with time dependent diagnostic results to simulate the transport process of 30 s long pulse deuterium plasma discharges in the EAST, obtaining the time dependent fast ion distribution, neutron emission spectrum, and total neutron emission rate. Combined with the time trace of the result measured by a standard 235U fission chamber, the effects of different configurations of NBI heating in EAST fusion plasmas have been evaluated.

3.
Rev Sci Instrum ; 92(4): 043506, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243369

RESUMO

Stilbene crystal detectors are widely used as fast neutron measurement tools based on recoil proton detection, such as liquid scintillators. A compact stilbene crystal neutron spectrometer (CSCNS) has been installed at the Experimental Advanced Superconducting Tokamak (EAST) to obtain information on fuel ions produced in the plasma core because of its merits of good n/γ discrimination capability, high detection efficiency, and fast response. For the first time, CSCNS has been used for neutron emission spectroscopy measurements in EAST plasmas with neutral beam injection (NBI) heating. The CSCNS has the same horizontal line of sight as the time-of-flight enhanced diagnostics neutron spectrometer. Under NBI heating scenarios, the time trace of the neutron yield monitored by the CSCNS is similar to the one monitored by a standard 235U fission chamber. The experimental pulse height spectra are also similar to the simulated ones generated by folding the simulated neutron energy spectrum with the detector response functions. These results demonstrate the capability of the CSCNS for neutron diagnostics and the study of fast-ion physics in EAST.

4.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 56(3): 294-300, 2021 Mar 09.
Artigo em Chinês | MEDLINE | ID: mdl-33663162

RESUMO

Liposomes are spherical vesicles with bilayer membrane structure spontaneously formed by phospholipids dispersed in an aqueous medium. Liposomes are excellent drug carrier with amphiphilic properties. Liposomes have good biocompatibility, biodegradability and no immunogenicity. Liposomes can achieve the delivery of the drug, enhance the solubility, improve the stability, reduce the toxic effect of the drug, and improve the therapeutic effect of the loaded drug. In recent years, liposome drug delivery systems have been widely used in dentistry. This article reviews the application of liposome drug delivery systems in caries, dental pulp diseases, periodontitis, implantation, oral anesthesia and oral candidiasis.


Assuntos
Lipossomos , Medicina Bucal , Portadores de Fármacos , Sistemas de Liberação de Medicamentos , Solubilidade
5.
Neoplasma ; 67(5): 1139-1145, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32412773

RESUMO

Beta-glucosidase (GBA), also known as acid ß-glucosidase, exhibits an activity of glucosylceramidase (EC 3.2.1.45). Three main isoforms of ß-glucosidases have been identified in mammals: GBA1, GBA2, and GBA3. The deficiency of these enzymes leads to glucosylceramide accumulation, resulting in Gaucher's disease. The present study is focused on the cytosolic ß-glucosidase, GBA3, and its relationship with hepatocellular carcinoma (HCC). The expression of GBA3 mRNA in HCC was evaluated first using the TCGA database, and then by immunohistochemistry using tissue microarrays of 328 clinically characterized HCC samples and 151 non-tumor liver controls. Moreover, the presence of a correlation between GBA3 expression and clinicopathological characteristics of patients was examined. The obtained results indicated that the expression of GBA3 mRNA was significantly lower in HCC than in the adjacent non-tumor liver tissues. The expression of GBA3 was inversely related to the number of tumors (p=0.041), tumor size (p<0.001), Edmondson grade (p=0.007), microvascular invasion (p=0.049), patient status (p<0.001), and α-fetoprotein level (p<0.001). Patients exhibiting low GBA3 expression had a shorter survival time than those with high expression (p<0.001). In conclusion, the decreased GBA3 expression is strongly associated with a poor prognosis in HCC patients, and GBA3 may be a potential therapeutic target for HCC.


Assuntos
Carcinoma Hepatocelular/genética , Neoplasias Hepáticas/genética , beta-Glucosidase/genética , Biomarcadores Tumorais , Carcinoma Hepatocelular/diagnóstico , Humanos , Imuno-Histoquímica , Neoplasias Hepáticas/diagnóstico , Prognóstico
6.
Rev Sci Instrum ; 90(12): 123510, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893803

RESUMO

A new gamma ray spectrometer with high energy and time resolutions has been developed and installed on the EAST tokamak to study fast ion and runaway electron behaviors. The spectrometer is based on a LaBr3(Ce) scintillator detector and a fully digital data acquisition system that is based on a digitizer with digital pulse processing algorithms. The energy resolution of the spectrometer is about 3.9% at 662 keV, and the spectrometer can operate stably at a counting rate as high as 1 MHz, monitored by using a light emitting diode monitoring system. The measured gamma ray spectrum is simulated based on Geant4 and unfolded with the high-resolution boosted Gold deconvolution algorithm, aiming at reconstructing the energy distribution functions of fast ions and runaway electrons.

7.
Rev Sci Instrum ; 89(10): 10I143, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399689

RESUMO

The Time-Of-Flight Enhanced Diagnostics (TOFED) neutron spectrometer with a double-ring structure has been installed at the Experimental Advanced Superconducting Tokamak (EAST) to perform advanced neutron emission spectroscopy diagnosis for deuterium plasma. In order to reduce the random coincidence from the background neutrons and gamma-rays, TOFED was moved outside the experimental hall and placed in the newly-built nuclear diagnostics laboratory in 2017. In this paper, the instrument-specific weight functions of TOFED are derived by taking the instrument response matrix and the radial line of sight in this new layout into consideration. The results show that the instrument is predominantly sensitive to counter-passing particles in the region where time-of-flights < 69.4 ns, while events at higher time-of-flights (corresponding lower neutron energies) are mostly representative of co-passing ions. The instrument-specific weight functions express the relationship between data in a given channel of the spectrum and the velocity space region that contributes to that. The results can be applied for energetic particle physics studies at EAST, in particular to compare data from different diagnostic techniques.

8.
Rev Sci Instrum ; 89(10): 10I141, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399743

RESUMO

Several compact neutron spectrometers are now installed at EAST (Experimental Advanced Superconducting Tokamak) to obtain information on fuel ions produced in the core of the plasma. In this paper, a stilbene crystal neutron spectrometer and an EJ301 liquid scintillator neutron spectrometer with n-γ discrimination capability will be discussed. Both spectrometers have a horizontal line of sight, while at different positions. In the last few experiment campaigns at EAST, they all proved to be reliable diagnostics for auxiliary heated D-D plasmas. Taking the response function simulated by dedicated Geant4 models into consideration, the velocity-space sensitivities given by the instrument-specific weight function of the beam-thermal part of neutron energy spectra in D-D plasmas are derived for both spectrometers with the Genesis code. This method makes it possible to directly relate the contribution of different deuteron velocity space regions to events in each channel of the neutron spectrum measured by the two instruments: http://rsi-htpd.peerx-press.org/.

9.
Eur Rev Med Pharmacol Sci ; 22(2): 382-387, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29424923

RESUMO

OBJECTIVE: Cisplatin is an important anti-cancer drug. However, the molecular mechanism of cisplatin on inhibition of the proliferation of liver cancer cells is unclear. Thus, we aimed to investigate the regulatory role of cisplatin on the growth and apoptosis of hepatoma LM3 cells. MATERIALS AND METHODS: LM3 cells were treated with cisplatin (2 µmol/L) for 48 h. MTT assay, flow cytometry, and caspase-3 activity assay were used to detect the growth, proliferation and apoptosis of LM3 cells. Western blot was applied to detect the expression of the inhibitor of apoptosis protein, XIAP. siRNA was used to knockdown the level of XIAP followed by cisplatin (2 µmol/L) treatment, and then the apoptosis of LM3 cells was measured. RESULTS: The treatment of cisplatin significantly inhibited the growth but induced the apoptosis of LM3 cells. Cisplatin also downregulated the expression of XIAP. The downregulation of XIAP by using siRNA enhanced the apoptosis of LM3 cells induced by cisplatin. CONCLUSIONS: Downregulation of XIAP enhanced the proapoptotic effect of cisplatin on LM3 cells, suggesting that XIAP might be used as a potential target in the treatment of liver cancer.


Assuntos
Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Cisplatino/farmacologia , Regulação para Baixo/efeitos dos fármacos , Proteínas Inibidoras de Apoptose Ligadas ao Cromossomo X/metabolismo , Carcinoma Hepatocelular/patologia , Caspase 3/metabolismo , Linhagem Celular Tumoral , Humanos , Neoplasias Hepáticas , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Interferência de RNA , RNA Interferente Pequeno/metabolismo , Proteínas Inibidoras de Apoptose Ligadas ao Cromossomo X/antagonistas & inibidores , Proteínas Inibidoras de Apoptose Ligadas ao Cromossomo X/genética
10.
Fa Yi Xue Za Zhi ; 34(6): 625-630, 2018 Jun.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-30896100

RESUMO

OBJECTIVES: To investigate the curative effects of various infusion volumes on liver-related metabolic mechanism in the treatment of hemorrhagic shock. METHODS: A severe hemorrhagic shock rabbit model was established in 30 rabbits. The rabbits were randomly divided into three groups: non-infusion group (A), conventional infusion group (B), and excessive infusion group (C) (n=10 in each group). Taking group B as the control, groups A and C were observed for the damage of non-infusion and excessive infusion, respectively. The outcomes in the three groups and their relations with liver tissue metabolism changes were analyzed with gas chromatograph-mass spectrometer (GC-MS). RESULTS: The mortality in groups A, B, and C group were 80%, 0%, and 70%, respectively. The liver tissue metabolic profile in group B showed statistically significant difference compared with that in groups A and B. In group C, the levels of 21 metabolites were lower than those in group B, and the levels of 8 metabolites were lower than those in group A. The relative contents of various metabolites were correlated with infusion volumes, and the succinic acid content was associated with death events (P<0.05). CONCLUSIONS: The conventional infusion has significant curative effect on hemorrhagic shock. The metabolites of liver tissues with excessive infusion are generally decompensated and have longer survival time than those in non-infusion group, which may caused by the excessive infusion-induced blood volume increase after hemorrhagic shock. Tissue fluid dilution is an important cause of death.


Assuntos
Hidratação , Fígado , Choque Hemorrágico , Animais , Fígado/metabolismo , Coelhos , Distribuição Aleatória
11.
Mol Med Rep ; 16(1): 533-538, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28560444

RESUMO

Schisandrin B is an active monomer of the Chinese magnolia vine (Schisandra chinensis) that can reduce transaminase activity in liver cells, inhibit lipid peroxidation, enhance antioxidant status, has protective effects in the liver and has antitumor effects. The present study investigated the potential protective effects of schisandrin B on the p53 signaling pathway in attenuating the inflammatory response, oxidative stress and apoptosis induced by traumatic spinal cord injury (TSCI) in adult rats. Behavioral examination, inclined plate test and spinal cord water content were used to evaluate the protective effect of schisandrin B in TSCI rats. The expression levels of superoxide dismutase (SOD), malondialdehyde (MDA), nuclear factor (NF)­κB subunit p65 and tumor necrosis factor (TNF)­α were examined using ELISA kits. Western blot analysis was performed to analyze the protein expression of caspase­3 and phosphorylated (p)­p53 in TSCI rats. In the present study, schisandrin B improved behavioral examination results and the maximum angle of inclined plate test, and inhibited spinal cord water content in rats with TSCI. Notably, schisandrin B reduced the activation of traumatic injury­associated pathways, including SOD, MDA, NF­κB p65 and TNF­α, in TSCI rats. In addition, schisandrin B suppressed the TSCI­induced expression of caspase­3 and p­p53 in TSCI rats. These results indicated that schisandrin B may attenuate the inflammatory response, oxidative stress and apoptosis in TSCI rats by inhibiting the p53 signaling pathway in adult rats.


Assuntos
Anti-Inflamatórios/farmacologia , Apoptose/efeitos dos fármacos , Lignanas/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Compostos Policíclicos/farmacologia , Transdução de Sinais/efeitos dos fármacos , Traumatismos da Medula Espinal/metabolismo , Proteína Supressora de Tumor p53/metabolismo , Animais , Anti-Inflamatórios/química , Biomarcadores , Caspase 3/metabolismo , Ciclo-Octanos/química , Ciclo-Octanos/farmacologia , Modelos Animais de Doenças , Lignanas/química , Masculino , NF-kappa B/metabolismo , Compostos Policíclicos/química , Ratos , Traumatismos da Medula Espinal/tratamento farmacológico , Traumatismos da Medula Espinal/patologia , Fator de Necrose Tumoral alfa/metabolismo
12.
Rev Sci Instrum ; 87(11): 11D836, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910376

RESUMO

The 2.5 MeV TOFED (Time-Of-Flight Enhanced Diagnostics) neutron spectrometer with a double-ring structure has been installed at Experimental Advanced Superconducting Tokamak (EAST) to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas. This work describes the response function of the TOFED spectrometer, which is evaluated for the fully assembled instrument in its final layout. Results from Monte Carlo simulations and dedicated experiments with pulsed light sources are presented and used to determine properties of light transport from the scintillator. A GEANT4 model of the TOFED spectrometer was developed to calculate the instrument response matrix. The simulated TOFED response function was successfully benchmarked against measurements of the time-of-flight spectra for quasi-monoenergetic neutrons in the energy range of 1-4 MeV. The results are discussed in relation to the capability of TOFED to perform beam ion studies on EAST.

13.
Rev Sci Instrum ; 87(11): 11D823, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910604

RESUMO

A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.

14.
Rev Sci Instrum ; 87(11): 11D822, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910679

RESUMO

This work presents measurements done at the Peking University Van de Graaff neutron source of the response of single crystal synthetic diamond (SD) detectors to quasi-monoenergetic neutrons of 14-20 MeV. The results show an energy resolution of 1% for incoming 20 MeV neutrons, which, together with 1% detection efficiency, opens up to new prospects for fast ion physics studies in high performance nuclear fusion devices such as SD neutron spectrometry of deuterium-tritium plasmas heated by neutral beam injection.

15.
Genet Mol Res ; 14(1): 1932-41, 2015 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-25867339

RESUMO

Y chromosome microdeletions can cause male infertility and are classified as natural transmission and de novo mutations. To examine the source of these deletions in Chinese men and to provide a theoretical and laboratory basis for genetic counseling, patients from Northeast China with primary male infertility (N = 22) and their fathers were investigated. Karyotype analysis was performed on peripheral blood lymphocytes using standard G-banding. Multiplex polymerase chain reaction amplification using 18 specific sequence-tagged sites was selected to detect Y chromosome microdeletions. De novo mutations were observed in 17 father-son pairs, leading to a mutation rate of 77.27% (17/22), while the vertical transmission of Yq AZFc microdeletions was detected in 5 cases of the families investigated (29.41%, 5/17). There were no statistically significant differences between vertically transmitted and de novo mutations in men with AZFc deletions regarding age, testicular volume, and reproductive hormone levels. Most Y chromosome microdeletions in men from Northeast China are the result of de novo mutations via natural conception, and men with Yq AZFc deletions showed no clear differences between vertical transmission and de novo mutations.


Assuntos
Povo Asiático/genética , Infertilidade Masculina/genética , Transtornos do Cromossomo Sexual no Desenvolvimento Sexual/genética , China , Bandeamento Cromossômico , Deleção Cromossômica , Cromossomos Humanos Y/genética , Deleção de Genes , Humanos , Cariótipo , Cariotipagem , Masculino , Linhagem , Análise de Sequência de DNA , Sitios de Sequências Rotuladas , Aberrações dos Cromossomos Sexuais
16.
Rev Sci Instrum ; 85(11): 11D829, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430242

RESUMO

The novel neutron spectrometer TOFED (Time of Flight Enhanced Diagnostics), comprising 90 individual photomultiplier tubes coupled with 85 plastic scintillation detectors through light guides, has been constructed and installed at Experimental Advanced Superconducting Tokamak. A dedicated magnetic shielding system has been constructed for TOFED, and is designed to guarantee the normal operation of photomultiplier tubes in the stray magnetic field leaking from the tokamak device. Experimental measurements and numerical simulations carried out employing the finite element method are combined to optimize the design of the magnetic shielding system. The system allows detectors to work properly in an external magnetic field of 200 G.

17.
Rev Sci Instrum ; 85(11): 11D830, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430243

RESUMO

A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

18.
Rev Sci Instrum ; 85(11): 11E112, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430291

RESUMO

The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/Ep) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms of the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.

19.
Rev Sci Instrum ; 85(11): 11E115, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430294

RESUMO

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation.

20.
Rev Sci Instrum ; 85(11): 11E417, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430324

RESUMO

To assess the neutron energy spectra and the neutron dose for different positions around the Experimental Advanced Superconducting Tokamak (EAST) device, a Bonner Sphere Spectrometer (BSS) was developed at Peking University, with totally nine polyethylene spheres and a SP9 (3)He counter. The response functions of the BSS were calculated by the Monte Carlo codes MCNP and GEANT4 with dedicated models, and good agreement was found between these two codes. A feasibility study was carried out with a simulated neutron energy spectrum around EAST, and the simulated "experimental" result of each sphere was obtained by calculating the response with MCNP, which used the simulated neutron energy spectrum as the input spectrum. With the deconvolution of the "experimental" measurement, the neutron energy spectrum was retrieved and compared with the preset one. Good consistence was found which offers confidence for the application of the BSS system for dose and spectrum measurements around a fusion device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA